Honeywell

Honeywell CC-TDOD61 51307089-175 Experion Series C 12-inch Redundant Digital Output IOTA

SKU CC-TDOD61 51307089-175

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: CC-TDOD61 51307089-175

  • Country of origin:United States

  • Product Type: Digital Output IOTA

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 124 x 304 x 65 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Overview

Honeywell CC-TDOD61, part 51307089-175, is the 12-inch redundant IOTA for the Series C CC-PDOD51 digital output module.

Honeywell’s Series-C I/O specification pairs CC-PDOD51 with CC-TDOD51 for non-redundant installations and CC-TDOD61 for redundant installations. The listed output type is sink, with 0.1 A output current and 1000 V isolation.

Features

  • Redundant System Architecture: Accommodates dual I/O modules on a single 12-inch assembly for hot-backup switchover with zero switchover gap time.
  • 32-Channel Switching Capability: Delivers 32 discrete digital output channels engineered for open-drain (sinking) load control.
  • Integrated Power Carrier Interface: Mounts directly to the 24 VDC system power bus carrier to supply operational power to the attached IOM and field circuits without external jumpers.
  • Galvanic Isolation: Provides up to 1000 VAC RMS system-to-field isolation when using user-supplied external field power.
  • Flexible Excitation Architecture: Supports configuration choices for internal system power or external field excitation.
  • Detachable Terminal Blocks: Features two-level removable screw-terminal blocks accepting field conductors up to 12 AWG (2.5 mm squared).
  • Thermal Management Design: Incorporates the Series C tilted vertical form factor to maximize cabinet packing density and promote vertical convection cooling.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model Number CC-TDOD61
Series Experion Series C
Product Type Digital Output Input Output Termination Assembly (IOTA)
Configuration Redundant
Physical Size 12 inches (304 mm)
Applicable IOM Model CC-PDOD51
Number of Output Channels 32
Compatible Output Type Sink (Open Drain)
Operating Voltage Range 15 to 30 VDC Maximum
Channel Output Current 0.1 A Maximum per channel
On-State Voltage 0 VDC (at 0.1 A load current maximum)
Off-State Voltage 24 VDC (typical)
Off-State Leakage Current 100 uA maximum
Switching Turn-On / Turn-Off Time 10 ms maximum
Redundancy Switchover Gap 0 ms
System-to-Field Galvanic Isolation 1000 VAC RMS (with user-supplied field power)
Field Wiring Termination Size Up to 12 AWG / 2.5 mm squared stranded wire

Connections / Interfaces

Connection Point Description / Function
IOM Mounting Slots Dual primary and redundant card slots for CC-PDOD51 modules
Field Terminal Blocks Two-level detachable screw terminals for 32 channel field wiring
Bus Power Interface Direct carrier screw mounting for 24 VDC system power rail
Ground / Return Interface System common and field isolation return terminals

Installation Guidelines

  1. Pre-Installation Inspection: Unpack the IOTA and inspect the assembly for physical damage. Verify that the unit model number is CC-TDOD61 and confirm compatibility with the target CC-PDOD51 IOMs.
  2. Mounting: Secure the 12-inch IOTA onto the Series C system cabinet mounting channel. Ensure all base retention screws are tightened to maintain ground continuity and connect to the 24 VDC power carrier bus.
  3. Field Wiring Connection: Strip field wire ends appropriately and land discrete sinking load connections on the two-level detachable terminal block assemblies. Acceptable wire range is up to 12 AWG (2.5 mm squared).
  4. Power Selection: Select internal power distribution or connect an isolated external 24 VDC field power supply according to system isolation requirements.
  5. IOM Installation: Align and press the primary and redundant CC-PDOD51 Digital Output Modules into their respective IOTA guide slots until fully seated and latched.

Configuration and Replacement Guidelines

  • Safe-State Configuration: Ensure the individual channel FAILOPT parameters (Hold Last Value or Shed to Safe State) are established in the C300 controller engineering repository prior to system commissioning.
  • Hot-Swapping IOMs: On a redundant CC-TDOD61 assembly, an individual CC-PDOD51 module can be removed or inserted under power without interrupting field output operations on the active partner module.
  • Maintenance Verification: Before servicing field devices or replacing connected loads, verify field supply voltage levels at the IOTA terminals using a calibrated multimeter.

FAQ

What is the primary function of the Honeywell CC-TDOD61?

The Honeywell CC-TDOD61 is a 12-inch redundant Input Output Termination Assembly (IOTA) designed for the Experion Series C system. It acts as the physical mounting, field wiring termination, and power distribution interface for 32 discrete sinking digital output channels using CC-PDOD51 modules.

Which I/O module is compatible with the CC-TDOD61 IOTA?

The assembly is specifically engineered to hold and interface two CC-PDOD51 SINK TYPE 24 VDC Digital Output Modules in a redundant configuration.

Does the CC-TDOD61 support hot-swapping during maintenance?

Yes, because the assembly supports redundant CC-PDOD51 modules, an individual module can be unseated and replaced without interrupting continuous 24 VDC digital output signals to field loads.

What level of electrical isolation is provided by this assembly?

When operated with an external field power supply, the unit provides 1000 VAC RMS galvanic isolation between the Experion system logic and field-side wiring.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TDOD61 51307089-175 Experion Series C 12-inch Redundant Digital Output IOTA

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Technical knowledge

Allen-Bradley 1771-IG: TTL Logic and 5 V Wiring Checks

Check 1771-IG TTL HIGH/LOW logic thresholds, field supply ripple and 1771-WC wiring before replacing an input module.

AKS 33 vs AKS 3000: Checks Before Replacing a Pressure Transmitter

A field checklist for distinguishing Danfoss 060G2105, 060G1323 and 060G2109 by pressure range, fitting, loop signal and controller scaling.

Diagnosing DeltaV SE5009 Power Problems Before Replacement

A field checklist for separating 24 VDC input, carrier bus, output derating and alarm-contact faults before replacing an Emerson SE5009.

Commissioning Quantum Inputs with the 140XSM00200 Simulator

A controlled commissioning method for using the 140XSM00200 simulator to verify Modicon Quantum input mapping and interlocks before reconnecting field wiring.

Commissioning PLX32-EIP-MBTCP: Subnets, Registers, and RPI

A commissioning checklist for the ProSoft PLX32-EIP-MBTCP covering subnet separation, register contracts, EtherNet/IP timing, failure tests and replacement records.

Diagnosing IC693MDL916 Relay Outputs Before Module Replacement

A field checklist for IC693MDL916 relay commands, terminal blocks, load current, switching rate and contact-side measurements.